Download the brochure

Robotized remote treatment.

Thanks to its exclusive MLS® multidiode applicator with 75W Peak Power, M8 provides rapid and automatic delivery of MLS® Laser Therapy.

The movement of the column and arm and rotation of the head in 5 robotized directions, enable perfect positioning on the target area.

The enhanced MLS® pulse results in faster improvement of symptoms with reduced treatment times in “hands-free” mode.

Please accept statistics cookies to watch this video.
Testo a Destra
Immagine 60%/Testo 40%
M8 automatic laser treatment

Hands-free in total safety

Once the treatment parameters have been entered, the therapist just needs to supervise the treatment which is performed hands-free at a distance, in total safety. There is no contact between the robotised head and the patient, thus avoiding potential contamination.

Testo a Destra
Immagine 60%/Testo 40%
M8 monitor - user interface

Assisting the operator

Therapy protocol and head adjustment parameters are displayed and can be changed via an advanced and user-friendly interface.
The new software offers complete protocols with relevant illustrations to guide the operator during the therapy.

3D M8

Note: once the product has been zoomed from Desktop, hold the right mouse key pressed to vertically navigate the product. Augmented Reality (AR) is active via smartphone: make M8 part of your centre now!

Testo a Destra
Immagine 30%/Testo 60%
ASAlaser's products are EU-MDR

EU MDR Certification

The M8 EU MDR certified protocols are available for both the robotic head and for the handpiece, creating a total synergy between the user’s professionalism and the automation of the robot.

Read more details

Technical characteristics
  • Robotized optical group with 3 MLS® sources with power up to 3.45 W - Peak Power 3 x 75 W 
    Target Area ø 5 cm highlighted by high-efficiency red LEDs
  • Handpiece with optical group consisting of MLS® source with power up to 1.15 W - Peak Power 75 W 
    Target Area ø 2 cm highlighted by high-efficiency red LEDs
  • High resolution LCD colour touch screen user interface
  • Simultaneous management of two independent channels
  • Treatment modalities:
    - Point-by-Point
    - Scanning
  • Possibility to customize every treatment parameters 
  • Dedicated area to create and save new customised programmes for each terminal/applicator
  • MLS® modulation in CPW and FPW mode (synchronized emission of Continuous Pulsed Waves and Frequenced Pulsed Waves)
  • Modulation frequency from 1 to 2.000 Hz with 1 Hz steps
  • Power level 25%, 50%, 75% and 100%
  • Fixed duty cycle at 50% or variable
  • Treatment duration from 1” to 45’’ with 1” steps
  • Automatic calculation of the emitted energy according to the set parameters 

ALARMS AND SAFETY FEATURES

  • Laser emission warning light
  • Interlock
  • Acoustic signal selectable by operator
  • Date and time
  • Password to operate the device
  • Language option
  • Ready to be connected to the remote Laser emission signaling device 

INCLUDED ACCESSORIES

  • Nº 2 Laser Safety Goggles

SIZE AND WEIGHT

  • 106 x 43 x 154 cm
  • 43 Kg

POWER SUPPLY

  • 100/240Vac 50/60Hz 85/110VA
Equipment and security alarms
Specifications
Testo a Destra
Immagine 60%/Testo 40%
M8 laser treatment - research on covid inflammation

M8 & COVID-19

A case report concerning the use of MLS® Laser Therapy supporting a patient suffering from severe pneumonia caused by Covid-19 reported a significant improvement in some basic parameters (breathing indexes, radiological results, oxygen requirement) for several days and without the need for a breathing ventilator.

Read the scientific article

Invest in the well-being of your patients
Calculate your ROI

How many patients do you examine every week with problems with muscles, tendons, ligaments, and joints?
How many of them could you effectively treat with laser therapy?
Calculate the return on investment for an ASA device and contact us for more information.

Calculate your ROI
Patients Per Week treated with MLS® Laser Therapy
Avg. Number of treatments
(average between 6-8 for patient)
Price for one MLS® Laser Therapy treatment
Additional income per Single Patient thanks to MLS® Laser Therapy
 
Additional weekly income thanks to MLS® Laser Therapy
 
Additional monthly income thanks to MLS® Laser Therapy
 
Additional yearly income thanks to MLS® Laser Therapy
 
Purchase price for the MLS® Laser Therapy device
Patients needed to reach the break-even point / re-buy the device
 
Needed weeks to re-buy the device
 
Testo a Destra
Immagine 60%/Testo 40%
M6 robotic laser - MLS therapy

Do you know the Blue version?

M6.
Robotized MLS® with 25W peak power.

  • Robotized optical group with 3 MLS® sources with power up to 3.15 W. Peak Power 3 x 25 W
  • Handpiece with optical group consisting of MLS® source with power up to 1.05 W. Peak Power 25 W

DOWNLOAD THE BROCHURE

 

MLS® Laser Therapy

MLS® Laser Therapy

The patented Multiwave Locked System (MLS®) technology overcomes the limits of traditional laser therapy devices (LLLT, class 3B and class 4 lasers).

Discover MLS® Laser Therapy
Do you want to learn more?

Fill out the form or, if you prefer, call us at +39 0444 289200.

Information concerning personal data processing pursuant to article 13 of (EU) Regulation 2016/679

WHY WE ARE PROVIDING THIS INFORMATION
Pursuant to (EU) Regulation 2016/679 (hereafter "Regulation"), this page describes the processing methods of the personal data of users consulting the website which may be accessed electronically at the following address: www.asalaser.com
This information does not refer to other online websites, pages or services which can be reached through hyperlinks potentially shown in the websites, but which refer to resources beyond the domain of the Data Protection Supervisor.

DATA CONTROLLER
Data concerning identified or identifiable natural persons may be processed when consulting the above-quoted websites.
The Data Controller is ASA Srl, Via Galileo Galilei 23 – 36057 Arcugnano (VI), Phone 0444 289200, who may be contacted by email at the address asalaser@asalaser.com.

LEGAL BASIS OF THE PROCESSING
The personal data shown in this page are processed by the data controller as they are necessary to manage the website and in order to propose and carry out the services offered by said website on the basis of specific information notes and, where required, on the basis of express consent.

TYPES OF DATA PROCESSED AND PROCESSING PURPOSES

Browsing data
During their normal operation, the IT systems and software used to operate this website acquire some personal data whose transmission is implicit when using internet communications protocols.
This category of data includes IP addresses or the names and domains of the computer and terminal employed by the users, the URI/URL (Uniform Resource Identifier/Locator) addresses of the requests made, the time of the request, the method used to place a request to the server, the size of the file received in reply, the numeric code indicating the status of the reply given by the server (successful, error, etc.) and other parameters concerning the user’s operating system and IT environment.
These data, which are necessary to use the web services, are also processed in order:

  • to obtain statistical information concerning the use of the service (most visited pages, number of visitors per hourly or daily time band, geographical area of provenance, etc.);
  • to check the correct operation of the services offered.

Browsing data are not retained longer than the time necessary to ensure the website’s operation and are cancelled immediately after their aggregation (unless required by the Judicial Authority for investigating offences).

Data provided by the user
The optional, explicit and voluntary sending of messages to the contact addresses, as well as the compilation and forwarding of the forms on the website, leads to acquiring the contact details of the sender, necessary for the reply, as well as all personal data included in the communication.
Specific information notes will be available on the pages destined to providing certain services.

DATA RECIPIENTS
Pursuant to article 28 of the Regulation, the data recipients of information collected subsequent to consulting the above-quoted websites will be the parties designated as data processors for carrying out services of development, provision and operational management of the IT platforms employed.
Personal data collected are also processed by Data Protection Supervisor personnel, which act on the basis of specific instructions provided concerning the purpose and method of said processing.

DATA SUBJECT RIGHTS
Where envisaged, data subjects have the right to obtain access to their personal data and their amendment or cancellation, or the limitation of processing which concerns them or the right to oppose the processing (Articles 15 and subsequent of the Regulation). The appropriate application may be submitted to the contacts indicated above.

RIGHT TO COMPLAIN
Data subjects who believe that the processing of their personal data carried out through this website occurs in violation of the Regulation, have the right to lodge a complaint to the Data Protection Supervisor, as laid out in article 77 of said Regulation, or to act in the appropriate courts of law (art. 79 of the Regulation).