Download the brochure

Reward your passion.

M-Hi inherits the mechanisms of action of MLS®, preserving the scientific evidence of its mechanisms of action, as well as the safety of a globally established treatment.
No more struggling with complicated equipment or wasting time on cumbersome setups. Our intuitive user-friendly M-Hi has been designed and manufactured in Italy, with clinicians like you in mind.

Please accept statistics cookies to watch this video.
Testo a Destra
Immagine 30%/Testo 60%
M-Hi laser device - efficient

Efficient.

Patented technology, scientifically and clinically validated.

  • M-Hi is efficient in run-time and over time, thanks to advanced internal sensors that ensure durability and stability.
  • With +100 scientific publications and +20,000 devices installed all around the world, the patented MLS® Laser Therapy is scientifically and clinically proven.
Testo a Destra
Immagine 30%/Testo 60%
M-Hi laser device - safe

Safe.

Reliability in your hands.

  • M-Hi inherits the mechanisms of action of MLS®, evolving its technological features while delivering validated state-of-the-art protocols
  • Applying the most powerful protocol (es. osteoarthritis) in both Point-by-Point and Scan modality, M-Hi delivers the right energy mix to the target tissues through a pleasant feeling: always far from reaching the thermal damage threshold​.
Testo a Destra
Immagine 30%/Testo 60%
M-Hi laser device - Versatile

Versatile.

Suitable to all clinical environments and methods, for an intensive daily use.

  • Lightweight: ergonomic, easy to handle and to operate, M-Hi is always at your side.
  • Cordless: thanks to its interchangeable batteries, M-Hi ensures hours of treatments and freedom of movement.
  • Long lasting & High performing battery: M-Hi covers the entire working day without the need for recharging (at least 20 patients per day, for an average of 10min per patient). 
Please accept statistics cookies to watch this video.
Testo a Destra
Immagine 30%/Testo 60%
M-Hi laser device - adaptive

Adaptive.

Focus on your patients: M-Hi automatically adapts the protocols to your needs.

Thanks to the patented system of automatic lens recognition and parameters adjustment, M-Hi adapts the protocol to ensure the desired dosage values. The tissue-targeted protocols available for all body districts are extremely easy to follow: let them guide you to immediate results.

Testo a Destra
Immagine 30%/Testo 60%
M-Hi laser device - accurate

Accurate.

No more guesswork: track the dose, objectify your therapy and replicate the results.

Dosage (J/cm2): Track the energy delivered per unit of treatment surface (J/cm2).

Evidence-based Medicine.

Safety and effectiveness of MLS® Laser Therapy are constantly proven at ASAcampus, the Joint Laboratory between ASA Research division and the Department of Biomedical and Clinical Experimental Science at the University of Florence – Italy, directed by Dr. Monica Monici.

Medical indications:

  • Osteoarthritis1
  • Rheumatoid Arthritis2
  • Bursitis3
  • Sprain/Contusion4
  • Tendinopathies5
  • Myalgia/Contracture (from myofascial pain syndrome, trigger points, muscle spasms, postural or traumatic causes) 6

1 From mild to moderate stages (up to 3rd grade) with high level of clinical evidence on knee, moderate on shoulder, wrist, hip, ankle, lumbar region;
2 From very low to severe stages with moderate level of clinical evidence on hand;
3From mild to severe pain with moderate level of clinical evidence on elbow, knee, ankle, toe;
4 From mild to moderate injury (up to 2nd grade sprain, without complete ligament tear) with moderate level of clinical evidence on knee, ankle, wrist, finger;
5 From mild to severe pain and disability levels with moderate level of clinical evidence on shoulder, elbow, wrist, finger, knee, ankle, foot;
6 From mild to severe pain and disability levels with moderate/moderate-high level of clinical evidence on shoulder, cervical, lumbar and temporomandibular regions.

 

Tailored treatments.

Whether you wish to treat large areas, trigger points, intra-articular windows in close contact or at a distance, M-Hi is equipped with the optical terminal that fits your needs.

  • Ø 2 cm collimated lens - 3 cm2 target area: versatile lens suitable for any type of application.
  • Ø 5 cm collimated lens - 20 cm2 target area: homogeneous irradiation of large volumes of tissue in a short time, from contact up to 30 cm distance.
  • Ø 4 mm lens - 0.13 cm2 target area: conical light guide designed for rapid, targeted and painless laser puncture treatments.
  • Ø 8 mm lens - 0.5 cm2 target area: curved light guide ideal for treating very localised and hard-to-reach painful areas, such as facial or interdigital points.

Modular device configuration

While the trolley allows swift movements inside the clinic , the handpiece holder arm ensures precise positioning on different body targets on all patients for a fixed point use.

Technical characteristics
  • Laser source with patented pulse MLS® up to 3.6 W
  • MLS® modulation in CPW and FPW (synchronised emission of Continuous Pulsed Wave and Frequenced Pulsed Wave)
  • Peak power outside handpiece: 270 W
  • Power level from 1% to 100%
  • MLS® pulse modulation frequency from 1 to 2000 Hz in 1 Hz steps
  • Treatment time from 1” to 30’00” in steps of 1”
  • Automatic calculation of the energy emitted according to the parameters set
  • Automatic recognition of the lens and parameters adaptation
  • Lens with target area highlighted by high efficiency red light LEDs
  • 10.1” high brightness LCD touchscreen display
  • Pre-set programs for 11 body districts
  • Programs section for laser puncture
  • Treatment images and videos
  • Possibility of customising each treatment parameter and save personal protocols
  • Treatment log to keep track of patients recovery path
  • Back-up system: a buffer battery keeps the device in stand-by mode when disconnected from the mains to allow the user to move it without having to switch it off
  • Statistics of device usage

POWER SUPPLY

  • 100-240 V AC 50/60 Hz 51-68 VA external power supply unit
  • Lithium-ion battery  (optional) 14,4V  6,9Ah; 0,5 kg

DIMENSIONS AND WEIGHT

  • 30 x 35 x 15 (W x D x H) cm; 4 kg (M-Hi)
  • 52 x 55 x 106 (W x D x H) cm; 23 kg (M-Hi + trolley + arm)

ACCESSORIES PROVIDED

  • N° 2 Laser Safety Goggles
  • Unit carrying case
  • Shoulder strap for portable use
  • Lens case attachable to the shoulder strap
  • 4 lenses:
    • Ø 4 mm (0,13 cm2)
    • Ø 8 mm (0,5 cm2)
    • Ø 2 cm (3 cm2)
    • Ø 5 cm (20 cm2)

OPTIONAL ACCESSORIES

  • Trolley: with storage compartment, 4 swivel wheels and self-locking system equipped with handpiece holder arm for fixed point use featuring sphere and joints
  • Battery kit: consisting of an exclusive charger, battery and connection cable, it allows the device to be used throughout the day without the need to plug it into the mains

ALARMS AND SAFETY EQUIPMENT

  • Laser emission warning light
  • Interlock
  • Acoustic signal adjustable by the operator
  • Date and time
  • Password to operate the device
  • Language option
  • Ready to be connected to the remote Laser emission signalling device
Equipment and security alarms
Specifications
MLS® Laser Therapy

MLS® Laser Therapy

The patented Multiwave Locked System (MLS®) technology overcomes the limits of traditional laser therapy devices (LLLT, class 3B and class 4 lasers).

Discover MLS® Laser Therapy
Do you want to learn more?

Fill out the form or, if you prefer, call us at +39 0444 289200.

Information concerning personal data processing pursuant to article 13 of (EU) Regulation 2016/679

WHY WE ARE PROVIDING THIS INFORMATION
Pursuant to (EU) Regulation 2016/679 (hereafter "Regulation"), this page describes the processing methods of the personal data of users consulting the website which may be accessed electronically at the following address: www.asalaser.com
This information does not refer to other online websites, pages or services which can be reached through hyperlinks potentially shown in the websites, but which refer to resources beyond the domain of the Data Protection Supervisor.

DATA CONTROLLER
Data concerning identified or identifiable natural persons may be processed when consulting the above-quoted websites.
The Data Controller is ASA Srl, Via Galileo Galilei 23 – 36057 Arcugnano (VI), Phone 0444 289200, who may be contacted by email at the address asalaser@asalaser.com.

LEGAL BASIS OF THE PROCESSING
The personal data shown in this page are processed by the data controller as they are necessary to manage the website and in order to propose and carry out the services offered by said website on the basis of specific information notes and, where required, on the basis of express consent.

TYPES OF DATA PROCESSED AND PROCESSING PURPOSES

Browsing data
During their normal operation, the IT systems and software used to operate this website acquire some personal data whose transmission is implicit when using internet communications protocols.
This category of data includes IP addresses or the names and domains of the computer and terminal employed by the users, the URI/URL (Uniform Resource Identifier/Locator) addresses of the requests made, the time of the request, the method used to place a request to the server, the size of the file received in reply, the numeric code indicating the status of the reply given by the server (successful, error, etc.) and other parameters concerning the user’s operating system and IT environment.
These data, which are necessary to use the web services, are also processed in order:

  • to obtain statistical information concerning the use of the service (most visited pages, number of visitors per hourly or daily time band, geographical area of provenance, etc.);
  • to check the correct operation of the services offered.

Browsing data are not retained longer than the time necessary to ensure the website’s operation and are cancelled immediately after their aggregation (unless required by the Judicial Authority for investigating offences).

Data provided by the user
The optional, explicit and voluntary sending of messages to the contact addresses, as well as the compilation and forwarding of the forms on the website, leads to acquiring the contact details of the sender, necessary for the reply, as well as all personal data included in the communication.
Specific information notes will be available on the pages destined to providing certain services.

DATA RECIPIENTS
Pursuant to article 28 of the Regulation, the data recipients of information collected subsequent to consulting the above-quoted websites will be the parties designated as data processors for carrying out services of development, provision and operational management of the IT platforms employed.
Personal data collected are also processed by Data Protection Supervisor personnel, which act on the basis of specific instructions provided concerning the purpose and method of said processing.

DATA SUBJECT RIGHTS
Where envisaged, data subjects have the right to obtain access to their personal data and their amendment or cancellation, or the limitation of processing which concerns them or the right to oppose the processing (Articles 15 and subsequent of the Regulation). The appropriate application may be submitted to the contacts indicated above.

RIGHT TO COMPLAIN
Data subjects who believe that the processing of their personal data carried out through this website occurs in violation of the Regulation, have the right to lodge a complaint to the Data Protection Supervisor, as laid out in article 77 of said Regulation, or to act in the appropriate courts of law (art. 79 of the Regulation).